Rasmus Larsen
posted this on March 11, 2010 14:09
Q:
Can the LEUART only be clocked by the low frequency oscillators?
A:
The LEUART can be clocked by the LFRCO, LFXO and the HFCORECLK divided by two. This is configured through the LFB field in CMU_LFCLKSEL. Note that the HFCORECLK will not be running in EM2/3.